Note: Observe the precautions given in Chapter 1.
Withdrawal
1. The fuel shut-off valve is located on top of the distributor head on the high pressure fuel pump. Clean the area around the valve first to prevent dirt from entering the fuel system.
2. To remove the valve, unscrew the nut and disconnect the wiring (see illustration).
3. Unscrew the valve and remove the O-ring, spring and plug.
Installation
4. Install in the reverse order, but before installing, clean all components and tighten the valve with the tightening torque specified specifications.