Order of execution
1. Remove distributor (cm. subsection 12.2.1.1).
2. Unfasten the two springs and remove the cover.
3. Remove runner.
4. Remove dust screen.
5. Mark the position of the anchor relative to the distributor shaft, remove the anchor and dowel pin.
6. Loosen the screws and remove the vacuum corrector.
7. Unscrew the screw and remove the Hall sensor with the shoe socket.
8. Loosen the screws and remove the fixed plate with gasket.
9. After disassembly, clean all parts and assemblies from dust and dirt.
10. Inspect the inside of the cover. If there are cracks or burnt out contacts, the cover must be replaced. Check the condition of the contact coil with the spring.
11. Create a vacuum in the vacuum corrector. Under the action of rarefaction, the thrust of the vacuum corrector must move. If this does not happen, then the diaphragm is torn and the vacuum corrector must be replaced.
12. Assemble the ignition distributor in reverse order.