Remove the lever bracket.
Remove the protective cover.
Set the selector lever to the "R" position.
Insert a 1mm thick flat feeler gauge.
Adjust the position of the switch contact if necessary so that the contact touches the probe.
Put the protective cover back in place.
Checking the electromagnetic switch of the selector lever lock: 1 - selector lever; 2 - flat feeler gauge; 3 - switch
Install the lever bracket and adjust its position so that the selector lever is at the same distance when moving from the "N" to "R" position and from the "N" to "O" position.
Tighten the bracket mounting bolt.
Screw the handle onto the selector lever.
This article was previously published on the resource Audimanual.ru