Remove the arm bracket.
Remove the protective cover.
Set the selector lever to position «R».
Insert a flat feeler gauge 1 mm thick.
Adjust, if necessary, the position of the switch contact so that the contact touches the probe.
Replace the protective cover.
Checking the electromagnetic switch for blocking the selector lever: 1 - selector lever; 2 - flat probe; 3 - switch
Install the lever bracket and adjust its position so that the selector lever is at the same distance when moving from the position «N» To «R» and out of position «N» To «ABOUT».
Tighten the bracket bolt.
Screw the handle onto the selector lever.