Withdrawal
Disconnect the wire from the negative battery terminal.
Remove the brake fluid from the reservoir with a syringe.
Disconnect the pipelines from the hydraulic unit.
hydraulic distribution block
Remove the relay cover.
Disconnect the plug connector of the hydraulic unit and disconnect the jumper from it on «mass».
Loosen the valve body bolt.
Remove the hydroblock
Installation
Guards put the hydroblock in place and connect the pipelines to the corresponding fittings of the block.
Tighten the valve body bolt.
Connect the plug connector of the hydroblock and attach a jumper to it on «mass».
Install relay protection.
Connect the wire to the negative terminal of the battery.
Add brake fluid to the reservoir and bleed the hydraulic brake system.