Warning: Do not attempt to open a system containing refrigerant yourself (refer to the warnings contained in paragraph 10). To open the system, contact a qualified technician. After completing the operation, ask him to install new o-rings and tube connections.
Withdrawal
1. Disconnect the wire "masses" from the battery.
2. Set the front panel to the position "maintenance", as described in chapter 11.
3. Entrust the opening of the system to a qualified specialist.
4. Remove the drive belt as described in the relevant part chapter 2.
5. Turn away bolts of fastening and disconnect refrigerant pipes from the compressor. Remove the o-rings and discard them - new ones are required for installation. Plug the connection openings to prevent dirt or moisture from entering the system.
6. From the rear of the compressor, disconnect the wiring connector for the magnetic clutch and, if applicable, from the shaft speed sensor.
7. Unscrew three (Nippondenso model) or four (Zaxel model) mounting bolt on the front of the compressor and remove it from the mounting bracket.
Installation
8. Installation - reverse procedure. Tighten all fasteners to the prescribed torque. At the end of the operation, have a qualified technician install new O-rings and charge the system with refrigerant.