Withdrawal
48. Disconnect the wire from the battery "masses".
49. Remove the glove box as described in chapter 11.
50. The servomotor is attached to the right stack of the heater fan housing.
51. Disconnect the wiring connector on the side of the motor.
52. Loosen the fastening screw and carefully remove the motor from the housing by turning the control lever and passing it through the hole in the housing.
Installation
53. Installation - reverse procedure. If the position of the control lever makes installation difficult, temporarily connect the battery and turn on the recirculation mode so that the drive lever is horizontal with the motor housing.
Visitor comments