Cooling and Heating Specifications General information The maximum pressure in the system is 1.2...1.5 bar Thermostat Opening temperature - 87°C (approximately) Minimum valve travel - less than...
Cooling system — general information General information 1. Cooling system - closed type, includes belt driven pump, aluminum radiator with electric fan (two fans), heater core, thermostat and...
Coolant hoses — disconnect and replace Note: Before starting the procedure, read the warnings contained in paragraph 1 of this chapter. Do not attempt to disconnect hoses on a hot engine to avoid...
Radiator — removal, inspection and installation Withdrawal 1. Disconnect the negative battery cable. Remove the front bumper as described in chapter 11 . 2. Drain the coolant, as described in the relevant...
Thermostat — removal, inspection and installation 1. The thermostat is in the left forward part of the block of cylinders. On late models 1.6 l (AHL engine), where the cooling system pump is driven by the...
Electric fan — check, removal and installation Additional electric fan Examination 1. The power supply to the fans is supplied through the ignition switch, a fuse and a pair of series-connected (service)...
Water pump — removal and installation Early models 1.6 L (AHL petrol engine) Withdrawal 1. Disconnect the negative cable from the battery, drain the coolant as described in chapter 1A . 2. Move the...