I 1. Screw; 2. Holder for coolant pipes; 3. Evaporator housing; 4. Coolant supply pipe for coolant flow from the engine; 5. Coolant supply pipe for return coolant flow to the engine; 6. Seal O-ring. Replace. Before installation, lightly lubricate the coolant; 7. Latch. These brackets are factory installed and hold the coolant pipes to the factory heat exchanger; 8. Heat exchanger of the heating system. This version is set by the manufacturer; 9. Fastening the coolant pipes in the replacement heat exchanger. Included in the scope of delivery of a replacement heat exchanger; 10. Washer. Included in the scope of delivery of a replacement heat exchanger; 11. Screw. Included in the scope of delivery of the replacement heat exchanger. Tightening torque 2.5 Nm; 12. Replaceable heat exchanger for the heating system. This version is supplied as a spare part. Cover the heat exchanger with foam insulation according to the climate, installation and vehicle design; 13. Cellular element. Provided for vehicles with a gasoline engine and for vehicles with a diesel engine, where the auxiliary heater (additional equipment) managed as an add-on Cover the cellular element with foam insulation according to the climate and installation design; 14. Additional heating element. heater -Z35-. Suitable for vehicles with diesel (also for vehicles with auxiliary heater (additional equipment) managed as an add-on). Cover the additional heating element. heater -Z35- with foam insulation according to climate design, installation; 15. Bracket; 16. Mounting plate with actuator motor for left temperature flap-V158-; 17. Defrost flap servomotor -V107-; 18. Left mounting plate with left footwell flap control motor -V108- and with center left control motor for air vent -V110-. With disc cams, intermediate lever and connecting rods. Lightly lubricate the cam guides, shaft bearings, and the journals on the damper arms (eg solid lubricating paste -G 000 150-); 19. Left heating element housing (with temperature dampers). The control of the temperature dampers and, accordingly, the housing of the left heating element is different on vehicles with climate control, installation version "Komfort" And "Basis". With climate, performance installation "Komfort" temperature dampers (front left and rear) driven by various electric motors. Various versions (with one or two bolted connections at the bottom). Lightly lubricate the cam guides, shaft bearings, gears, and the pins on the damper arms (eg Solid lubricating paste -G 000 150-); 20. Toothed segment; 21. Retaining plate with rear temperature flap actuator motor -V137-. Remove the mounting plate with the rear temperature flap control motor -V137-, remove the motor from the mounting plate. The control of the left and right temperature dampers is different for climate control units "Komfort" And "Basis". With climate, performance installation "Komfort" The rear left temperature flap shaft is driven via a toothed segment by the rear temperature flap actuator motor -V137-. The right rear temperature flap is also driven by the rear temperature flap actuator motor -V137- via a connecting rod that operates with this toothed segment. Lightly lubricate the shaft bearings, toothed segments, and the pins on the damper levers (eg solid lubricating paste -G 000 150-); 22. Defrost damper connecting rod; 23. Intermediate lever to defroster flap control motor -V107-; 24. Connecting rod for rear temperature flaps; 25. Climate air distributor housing. performance settings "Komfort". Do not disassemble for parts. Various versions on vehicles with climate control, installation in version "Komfort" And "Basis". Lightly lubricate the cam guides, shaft bearings, gears, and the pins on the damper arms (eg Solid lubricating paste -G 000 150-). With climate, performance installation "Komfort" separator set (for distribution into right and left/front and rear flows). Additionally, a deflector with covers is installed for indirect ventilation on the left and right, as well as for supplying air to the rear deflector of the center console on the left and right. Various dampers (e.g. front panel vents and footwells left and right) are driven by separate electric motors. The flaps of the central vents of the front panel and the air duct to the rear vents of the center console on the left and right are respectively connected to each other by connecting rods and are driven by the control electric motor center, left vent -V110- and the control electric motor center, right vent -V111-. Since 08.2007, air conditioners have been gradually installed with an air distributor housing with an optimal arrangement of air ducts (execution "1" And "2"); 26. Air vent temperature sensor, left footwell -G261-. Installed in the left air vent in the footwell; 27. Climate wiring harness, performance settings "Komfort". Various designs. Mark the location of the plugs before pulling them out (similar plugs for different actuator motors and temperature sensors, you can accidentally mix them up). Secure the wiring harness to the mounting points provided on the body using clamps or fasteners so that it does not come into contact with the moving components; 28. Right footwell air outlet temperature sensor -G262-. Installed in the right footwell vent; 29. Cable clamp; 30. Housing of the right heating element (with temperature dampers). The control of the temperature flaps and, accordingly, the housing of the right heating element is different on vehicles with climate control, installation version "Komfort" And "Basis". With climate, performance installation "Komfort" temperature dampers (front right and rear right) are driven by various actuator electric motors. Various versions (with one or two bolted connections at the bottom). Lightly lubricate the cam guides, shaft bearings, gears, and the pins on the damper arms (eg solid lubricating paste -G 000 150-); 31. Right mounting plate with right footwell flap control motor -V109- and with right center vent control motor -V111-. With disc cams, intermediate lever and connecting rods. Lightly lubricate the cam guides, shaft bearings, and the journals on the damper arms (eg solid lubricating paste -G 000 150-); 32. Retaining plate with actuator motor for right temperature flap -V159-
I 1. Screw; 2. Holder for coolant pipes; 3. Evaporator housing; 4. Coolant supply pipe for coolant flow from the engine; 5. Coolant supply pipe for return coolant flow to the engine; 6. Seal O-ring. Replace. Before installation, lightly lubricate the coolant; 7. Latch. These brackets are factory installed and hold the coolant pipes to the factory heat exchanger; 8. Heat exchanger of the heating system. This version is set by the manufacturer; 9. Fastening the coolant pipes in the replacement heat exchanger. Included in the scope of delivery of a replacement heat exchanger; 10. Washer. Included in the scope of delivery of a replacement heat exchanger; 11. Screw. Included in the scope of delivery of the replacement heat exchanger. Tightening torque 2.5 Nm; 12. Replaceable heat exchanger for the heating system. This version is supplied as a spare part. Cover the heat exchanger with foam insulation according to the climate, installation and vehicle design; 13. Cellular element. Provided for vehicles with a gasoline engine and for vehicles with a diesel engine, where the auxiliary heater (additional equipment) managed as an add-on Cover the cellular element with foam insulation according to the climate and installation design; 14. Additional heating element. heater -Z35-. Suitable for vehicles with diesel (also for vehicles with auxiliary heater (additional equipment) managed as an add-on). Cover the additional heating element. heater -Z35- with foam insulation according to climate design, installation; 15. Bracket; 16. Mounting plate with actuator motor for left temperature flap-V158-; 17. Defrost flap servomotor -V107-; 18. Left mounting plate with left footwell flap control motor -V108- and with center left control motor for air vent -V110-. With disc cams, intermediate lever and connecting rods. Lightly lubricate the cam guides, shaft bearings, and the journals on the damper arms (eg solid lubricating paste -G 000 150-); 19. Left heating element housing (with temperature dampers). The control of the temperature dampers and, accordingly, the housing of the left heating element is different on vehicles with climate control, installation version "Komfort" And "Basis". With climate, performance installation "Komfort" temperature dampers (front left and rear) driven by various electric motors. Various versions (with one or two bolted connections at the bottom). Lightly lubricate the cam guides, shaft bearings, gears, and the pins on the damper arms (eg Solid lubricating paste -G 000 150-); 20. Toothed segment; 21. Retaining plate with rear temperature flap actuator motor -V137-. Remove the mounting plate with the rear temperature flap control motor -V137-, remove the motor from the mounting plate. The control of the left and right temperature dampers is different for climate control units "Komfort" And "Basis". With climate, performance installation "Komfort" The rear left temperature flap shaft is driven via a toothed segment by the rear temperature flap actuator motor -V137-. The right rear temperature flap is also driven by the rear temperature flap actuator motor -V137- via a connecting rod that operates with this toothed segment. Lightly lubricate the shaft bearings, toothed segments, and the pins on the damper levers (eg solid lubricating paste -G 000 150-); 22. Defrost damper connecting rod; 23. Intermediate lever to defroster flap control motor -V107-; 24. Connecting rod for rear temperature flaps; 25. Climate air distributor housing. performance settings "Komfort". Do not disassemble for parts. Various versions on vehicles with climate control, installation in version "Komfort" And "Basis". Lightly lubricate the cam guides, shaft bearings, gears, and the pins on the damper arms (eg Solid lubricating paste -G 000 150-). With climate, performance installation "Komfort" separator set (for distribution into right and left/front and rear flows). Additionally, a deflector with covers is installed for indirect ventilation on the left and right, as well as for supplying air to the rear deflector of the center console on the left and right. Various dampers (e.g. front panel vents and footwells left and right) are driven by separate electric motors. The flaps of the central vents of the front panel and the air duct to the rear vents of the center console on the left and right are respectively connected to each other by connecting rods and are driven by the control electric motor center, left vent -V110- and the control electric motor center, right vent -V111-. Since 08.2007, air conditioners have been gradually installed with an air distributor housing with an optimal arrangement of air ducts (execution "1" And "2"); 26. Air vent temperature sensor, left footwell -G261-. Installed in the left air vent in the footwell; 27. Climate wiring harness, performance settings "Komfort". Various designs. Mark the location of the plugs before pulling them out (similar plugs for different actuator motors and temperature sensors, you can accidentally mix them up). Secure the wiring harness to the mounting points provided on the body using clamps or fasteners so that it does not come into contact with the moving components; 28. Right footwell air outlet temperature sensor -G262-. Installed in the right footwell vent; 29. Cable clamp; 30. Housing of the right heating element (with temperature dampers). The control of the temperature flaps and, accordingly, the housing of the right heating element is different on vehicles with climate control, installation version "Komfort" And "Basis". With climate, performance installation "Komfort" temperature dampers (front right and rear right) are driven by various actuator electric motors. Various versions (with one or two bolted connections at the bottom). Lightly lubricate the cam guides, shaft bearings, gears, and the pins on the damper arms (eg solid lubricating paste -G 000 150-); 31. Right mounting plate with right footwell flap control motor -V109- and with right center vent control motor -V111-. With disc cams, intermediate lever and connecting rods. Lightly lubricate the cam guides, shaft bearings, and the journals on the damper arms (eg solid lubricating paste -G 000 150-); 32. Retaining plate with actuator motor for right temperature flap -V159-
Visitor comments