Depending on the generator version, disconnect the electrical wires from the generator clamps or disconnect the generator connector.
Loosen the alternator mounting bolt and the alternator mounting nut to the tension bar and loosen the tension on the alternator drive belt.
Remove the alternator drive belt.
Turn up the tension bar.
Remove the protective casing of the generator if necessary.
After unscrewing the mounting bolt, remove the generator.
Install the generator in the reverse order of removal. then adjust the tension of the alternator drive belt.
Generator details: 1 - cover on the drive side; 2 - front bearing; 3 - flange; 4 - rotor; 5 - stator; 6 - cover from the side of slip rings; 8 - brush holder and voltage regulator; 9 - capacitor; 10 - rectifier unit; 11 - fan; 12 - pulley.
Visitor comments