Maximum system pressure |
1.2 - 1.5 bar
|
Thermostat | |
Opening temperature (approximately) |
87°
|
Minimum valve lift |
7 mm
|
Tightening torques, Nm
Alternator/Power Steering Pump Bracket Mount |
20
|
Cooling fan switch |
25
|
Cooling Fan Clutch |
20
|
Water pump: | |
4-cylinder engines: | |
Pump mounting bolts: | |
Gasoline engines |
20
|
Diesel engines: | |
– stage 1 |
20
|
– stage 2 |
Tighten by 90°
|
Bolts of fastening of the pump to a casing |
10
|
Pulley bolts |
25
|
5-cylinder engines: | |
Mounting bolts |
20
|
Bolts of fastening of a casing of the thermostat |
10
|