Warning: Individual characteristics are also given in the text of the Chapter and, if mandatory, are highlighted in bold
Design | Thermosyphon with a vane water pump. thermostatic adjustment. With separate expansion tank. Viscous fan clutch. Optional electric fan turns on and off thermal switch |
Coolant | soft water mixture (60%) and antifreeze concentrate (40%) |
Antifreeze concentrate | G12 (Red) (do not mix with any other) |
System volume | |
Engines 1.6, 1.8 l | 5.0 l |
The concentration of antifreeze in the coolant to ensure frost resistance up to | |
– 35°С | 50% |
– 25°C | 40% |
Thermostat | |
Start opening temperature | 87°С |
Full opening temperature | 102°C |
Valve stroke | not less than 7 mm |
Fan thermal switch | |
Switching on/off the 1st stage | 92–97/84–91°C |
2nd stage on/off | 99–105/91–98°С |
Expansion tank plug | |
Overpressure valve opens | 1.4–1.6 bar |
Vacuum valve opens | 0.06–0.1 bar |
Air conditioner refrigerant | |
Type | R134a |
Volume, gr. | 750 ± 50 |
Refrigerator oil | |
Type G052 | 154 A2 |
volume cmi | 135 ± 15 |
Tightening torques for threaded connections | |
Fastener tightening torques are also given in the text of the Chapter and on
some illustrations*. * Tightening torques in bold type are subject to strict adherence; Efforts not in bold are indicative only Water pump on engine | |
Engines | 15 Nm |
thermostat cover | 15 Nm |
Air conditioning compressor | 45 Nm |
Visitor comments