Withdrawal
Disconnect the ground wire in the battery with the ignition off. Remove soundproof screen. Cut the clamp -2- and remove the cover -3- from the solenoid relay upwards.
Loosen nut -2-. Where available, unscrew the jumper to the virgin motor mount. Remove the cover from the positive terminal. Disconnect cables -3- and -4- from retractable starter. Remove cable holder -1-. Remove the starter upper mounting bolt.
Loosen nut -2- and remove earth cable -3- at bottom of starter. Unscrew bottom double bolt -1- for starter. Pull starter down.
Installation
Install in reverse order, taking into account the following: during installation, install all clamps in the places where they were originally installed. Connect battery.
Tightening torques:
- Starter to engine: 65 Nm
- Terminal B+ to starter: 16 Nm
- Mass cable to starter: 22 Nm
- Holder to starter: 22 Nm