Withdrawal
Drain coolant. Detach coolant hoses -arrows- from coolant expansion tank and lay coolant hose loosely at top.
Unplug electrical connector -1- for low coolant level indicator sender -F66-. Remove nut -arrow- and remove coolant expansion tank. Lay wire B loosely on the holder. Lay engine wiring harness -2- loosely on support.
Carefully! Risk of damage to cable locks. Do not remove the cable locks from the shift lever and intermediate lever. Removed cable locks must be replaced.
Unlock the selector cable lock as follows: Pull out the safety mechanism on the selector cable -arrow 2- as far as it will go. Turn movable sleeve -arrow 3- as far as it will go and secure. Pull selector cable -1- out of cable lock.
Place a pallet for service cranes -VAS 6208- under the engine. Disconnect connector -2-. Detach coolant hose -1- from parametric engine cooling thermostat -F265-.
Unscrew bolts -arrows- and remove electronic engine cooling thermostat -F265-.
Installation
Install in reverse order, but the seal must be replaced. ring. Use clamps of the appropriate series to fasten all hose connections. Fill up the coolant.