Withdrawal
Remove bolts -arrows- for exhaust manifold pipe.
Disconnect connector -3-. Remove nuts -arrows-, remove pipe -1- for exhaust gas recirculation, exhaust gas recirculation valve -N18- with exhaust gas recirculation potentiometer -0212-pos. 2-.
Installation
Reinstall in reverse order, replacing gaskets.